® has been a pioneer in the construction industry with consistently innovating products and solutions to meet the ever-changing needs of Customer.
In the process of moving closer to meeting the expectations of our customers and solving some major challenges, we have come up with Exterior Drywalls.
Exterior Drywalls by Gyproc® is a one stop solution for achieving a light-weight sustainable solution as opposed to a Brick/Block work.
It is typically a partition system with GI frames in between encased by boards on either side and finished with suitable Jointing Compound ,added with a layer of waterproofing and rendering on the exterior surface.
Advantages of Exterior Drywalls
![Exterior wall with advertisement icon 1 Exterior wall with Gyproc advertisement icon 1](https://www.gyproc.in/images/ExteriorWall-ad-icon1.jpg)
Light Weight
![Exterior wall with advertisement icon 2 Exterior wall with Gyproc advertisement icon 2](https://www.gyproc.in/images/ExteriorWall-ad-icon2.jpg)
Faster Construction
![Superior acoustics Superior acoustics](https://www.gyproc.in/images/ExteriorWall-ad-icon3.jpg)
Superior Acoustics
![Exterior wall with advertisement icon 3 Exterior wall with Gyproc advertisement icon 3](https://www.gyproc.in/images/ExteriorWall-ad-icon4.jpg)
Energy Efficient
Better Performance, More Savings
![](https://www.gyproc.in/images/bpms-icn-1_03.jpg)
Structural Cost Saving Up to 15-17%
![](https://www.gyproc.in/images/bpms-icn-2_03.jpg)
Material Handling Saving Up to 50%
![Electricity Consumption Saving Icon](https://www.gyproc.in/images/bpms-icn-3_03.jpg)
Electricity Consumption Saving Up to 50%
![](https://www.gyproc.in/images/bpms-icn-4_03.jpg)
Reduced Water Consumption Compared to Masonry Up to 97%
![](https://www.gyproc.in/images/bpms-icn-5_03.jpg)
When Gyproc® Exterior walls meet performance, expect better ROI, best of results, and savings.
Design Standards & Certifications
![](https://www.gyproc.in/images/dsac-icn-1_03.jpg)
Design for Wind load as per IS 875 part 3
- Wind zone 4 & Wind speed - 47 m/sec
- Deflection criteria - L/360
- Design load - 1300 Pa
- Proof load - 1950 Pa
![Reduced Water Consumption - Icon](https://www.gyproc.in/images/dsac-icn-2_03.jpg)
Stability, Air & Water ingress Test
- F.I.T.I. – ASTM E283, E330, E331 & AAMA 501.1
![Star Icon](https://www.gyproc.in/images/dsac-icn-3_03.jpg)
Durability (Heat-Rain) Test
- IIT Madras - EN 12467 for 50 Cycles
![](https://www.gyproc.in/images/dsac-icn-4_03.jpg)
Acoustic Test
- A.R.A.I. - ASTM & ISO standard
- Acoustic Insulation (STC) – 56dB
![](https://www.gyproc.in/images/dsac-icn-5_03.jpg)
Fire Test
- Spectro labs – BS 476 Part 22
- Fire rating – 60 Minutes